You may also like to see...

M74

Instrument for safety test on electrical plants and TRMS integrated multimeter

Information

M74  is one of four models of new MULTITEST family of portable meters, which included also M72, M73 and M75 meters, designed to perform Global Earth Resistance measurements, trip out time test on AC RCD type, Insulation and Continuity of earth conductors according to VDE and IEC common standards on typical urban electrical installations. Powerful AUTOTEST feature permits to M74 to quickly perform an automatic sequence of the above tests directly to the plugs of electrical plants with OK or NOT OK response results. M74 meter also include others features as phase sequence with 1 wire method, leakage current with optional transducer clamp and a powerful DMM function for TRMS measures of voltage and current ideal for troubleshooting operations both in civil and industrial environments. Voltage and current peak measure on 1ms it’s also ok for inrush current evaluation of electrical motor devices. As each model of MULTITEST family also M74 have a large LCD display for easy readings, a modern and ergonomic external case, a innovative electronic function selector for easy to use and a protection rubber holder to prevent accidental damaged

Function
  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 250, 500VDC
  • Trip-out time of RCDs type AC Standard
  • Selectable test current; 30mA, 30x5mA, 100mA, 300mA
  • Global Earth Resistance without RCD tripping
  • Global Earth Resistance with 0.1 resolution
  • Automatic test of global earth resistance + RDC test + insulation test
  • DC Voltage
  • AC TRMS Voltage
  • Automatic detection of AC/DC signals
  • AC TRMS Current with optional external clamp
  • AC TRMS Leakage current with optional external clamp
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with optional external clamp
  • Phase sequence indication at 1 or 2 wires method
  • Phase coincidence indication at 1 or 2 wires method
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF

Codmetel : HV000074
Accessories
STANDARD
  • KIT0075 : Set 2 cables with leads  + 2 alligator clips
  • C2075 : Cable 2 wires with Shuko plug
  • BORSA75 : Carrying bag
  • ISO9000 calibration certificate
  • User manual on CD-ROM
  • Quick reference guide
OPTIONAL
  • HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm
  • HT4003 : Rigid clamp 400A AC, diameter 30mm
  • HT4004N : Transducer clamp 10-100A DC
  • Alligator clip black, 4 pcs
  • NOCANBA : Adapter Hypertac female/banana male
Standards
EMC 2004/108/CE Directive
16th edition
CE MARK
EN 61008
IEC/EN61557-1
IEC/EN61557-2
IEC/EN61557-3
IEC/EN61557-4
IEC/EN61557-6
IEC/EN61557-7
LVD 2006/95/CE Directive
VDE 0100